Comparison of different types of hearing protection devices for use during weapons firing
Abstract
Abstract
Résumé
INTRODUCTION
METHODS
Equipment
Set-Up
Hearing protection devices
Test procedure
Data analysis
RESULTS
Free-field source signal
Transfer function of the open ear
Impulse peak insertion loss
HPD | Left | Right | ||
---|---|---|---|---|
IPIL, dB | Range, dB | IPIL, dB | Range, dB | |
E-A-R Classic | 37.8 | 33.7–42.1 | 40.6 | 38.7–42.0 |
Combat Arms Green | 28.8 | 21.2–33.3 | 27.6 | 21.5–38 |
Combat Arms Yellow | 21.7 | 20.2–24.2 | 19.5 | 18.0–21.4 |
ETY·Plugs | 35.1* | 32.6–39.8* | 39.0* | 38.0–40.1* |
Peltor H10A | 19.2 | 15.1–21.6 | 17.1 | 12.8–25.6 |
Peltor H10A and EAR Classic | 49.5 | 46.1–54.3 | 48.7 | 45.7–51.2 |
Peltor PowerCom Plus | 31.6 | 30.3–34.6 | 34.1 | 31.5–37.8 |
Peltor H10A and glasses | 16.4 | 14.9–18.6 | 12.9 | 10.9–15.6 |
Peltor H10A, E-A-R Classic, and glasses | 47.3 | 46.3–48.5 | 44.1 | 40.5–47.6 |
Peltor PowerCom Plus and glasses | 15.6 | 14.3–16.3 | 8.7 | 5.2–10.8 |
IPIL = impulse peak insertion loss; HPD = hearing protection device.
DISCUSSION
ANSI/ASA S12.42 requirements not met
Insertion loss results
CONCLUSIONS
ACKNOWLEDGMENTS
REFERENCES
REGISTRY AND REGISTRATION NO. OF THE STUDY/TRIAL
ANIMAL STUDIES
PEER REVIEW
Information & Authors
Information
Published In
Copyright
History
Key Words:
Mots clés:
Authors
Contributors
Competing Interests
Funding
Ethics Approval
Informed Consent
Metrics & Citations
Metrics
Related Content
Citations
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.
Journal of Military, Veteran and Family Health 2015 1:2, 43-51